Events

IT Equipment Technical Specifications

LOT1: Hardware Devices Requirements

 

No Equipment Minimum requirement specifications
1 Desktop PC Make: HP

Processor (CPU): Intel Core i3-3xxx

Operating System: Microsoft Windows 7 Professional or 10, x64 bits or x32 bits

Microsoft Office Professional 2010 or 2013

Memory: 4 GB RAM

Storage: 500 GB internal hard drive

CD-ROM: DVD/CD-RW

Monitor/Display: 15″ LCD monitor

Other: Dual-band WiFi-certified 802.11 a/g – compliant adapter

2 Laptop PC Make: HP

Processor (CPU): Intel Core i3-3xxx

Operating System: Microsoft Windows 7 Professional or 10, x64 bits or x32 bits

Microsoft Office 2010 or 2013

Memory: 4 GB RAM

Storage: 500 GB internal hard drive

CD-ROM: DVD-RW/CD-RW

Monitor/Display: 13″ LCD monitor

Network Adapter: Dual-band WiFi-certified 802.11a/b/g/n – compliant adapter

Other: Internal or external Webcam, lock, carrying case

3 General Office Printer                                    (All In One: printer/ photocopier/ scanner) Brands: HP LaserJet Pro MFP M426fdn – multifunction printer (B/W) or equivalent.

Functions: Print/ Copy /Fax /Scan

Multitasking supported: Yes

Printing specifications

Fax Type: Plain paper

Printing Technology: Laser – monochrome

Monthly Duty Cycle (max): 80000 pages

Recommended Monthly Volume: 750 – 4000 pages

Display Diagonal Size: “3″

Display Features: tilt, touch screen

PC Connection Availability: Yes

PC Connection: Gigabit LAN, USB 2.0, USB host

Air Print Enabled: Yes

Office Machine Features: Google Cloud Print ready, save to USB flash drive, scan to Cloud, scan to e-mail, scan to network, HP Auto-On/Auto-Off Technology, HP ePrint, Instant-on Technology, Jet Intelligence Cartridge Technology, Mobile Printing, Mopria certified, print from USB flash drive, print from cloud.

OR:

Brands: HP Laser Jet Pro MFP M225 dn- multifunction printer

Print speed: Letter: Up to 40 ppm black; First Page Out: As fast as 5.4 sec Print Resolution: Black (best):600x600dpi,Up to4800x600 enhanced dpi; Black (fine lines):Up to 1200x1200dpi Print Resolution Technology: HP  Fast Res  1200,HP ProRes1200,600dpi Display:3″(7.5cm) touch screen Color Graphic Display (CGD) Standard connectivity:1Hi-Speed USB2.0;1HostUSB;1Gigabit Ethernet10/100/1000T network ;Easy access USB Mobile Printing Capability :HP Eprint, Apple Air Print™,Mopria  certified ,Google Cloud Print ,Mobile Apps Paper Handling:100-sheet tray1,250-sheet input tray2,150-sheet output bin ,Optional 550-sheet tray3.

4 Teller Printer (Dot Matrix Printer) EPSON LQ-2190 (Low Cost)

Printer Type: Workgroup printer

Max Sheets in Multi-Part Form: 6

Printer Connectivity Technology: Wired

Product Weight (kg): 13

Networking Type: None

Printing Technology: Dot-matrix

Nominal Voltage (V): AC 230V

Product Dimensions (mm): 639W x 402D x 256H mm

Packaged Quantity: 1

Brand: Epson

RAM Memory: 128 KB

Media Type: Envelopes,Labels,Plainpaper,Continuousforms,Cards

Language Simulation: EPSON ESC/P 2|IBM PPDS

Max Resolution B/W: 10 cpi

PC Connection Availability: Yes

PC Connection: Parallel|USB

Microsoft Certification: Compatible with Windows 7

Printing Output Type: Monochrome

Media Size Class: Other

Max Media Size: Roll (21.6 cm) |420 x 420 mm Continuous paper 101.6 mm – 406.4 mm (width)

Max Printing Speed B/W: 576 char/sec

Print head Type: 24 pin

Or

Epson FX2190 Printer

Or

Epson LQ 590 Printer is recommended or an up level of 590

N.B: Epson LQ 350 is exclusively not acceptable.

5 Bill counting machine Counter CR2: UV, MG and IR counterfeit detection.

Counting Speed: >1,500/minute.

Feeder Capacity: 400 bills,

Carrier Capacity: 300 bills.

Weight: 5kg.  Display: LED

OR

Counter CR180: UV and MG counterfeit detection.

Counting Speed: >1,000/minute.

Feeder Capacity: 300 bills, Carrier Capacity: 200 bill

6 Uninterrupted Power Supplier                                     (APC  SMART) 3 KVA(will be shared)

Model No. 3 KVA//2.7 KW
Technology Line Interactive
INPUT Voltage Range 175V~240V AC ±5V AC
Nominal Voltage 220V/230V/240V /AC
Frequency 50  Hz
Max. Current 9.6A
OUTPUT Nominal Voltage 220/230/240±2%VAC
Max. Current 6 A
Voltage Range
(Normal Mode)
220V/230V/240V/110V/120V AC ±10%
Voltage Range
(Battery Mode)
220V/230V/240V/110V/120V AC ±10%(Modified Sine Wave)
Frequency
(Normal Mode)
Synchronized(Sine Wave)
Frequency
(Battery Mode)
50/60Hz±0.5Hz
Waveform Modified Sine Wave
Power Factor 0.9
Efficiency >90%
Transfer Time <10ms
BATTERY &
RUNTIME
Battery Type Maintenance-free Sealed Lead-acid Battery, Leakproof
Included Battery
Modules
4*12V/7.0Ah
Runtime
(Half/Full Load)
Full Load
4.0 minutes
Half Load
15 minutes
Discharge Time 4*(PC+17″Mon)
>=6 minutes
Charge Time ≤12 Hours,Charging Up to 90%
Display Status LED (Normal,Backup,Faul

)

     
7 Generator 5-6 KVA

Rated A. C. output 5.0kW
Max. A. C. output 5.5kW
A. C. Frequency 50/60Hz
Rated Voltage 22

/110V

Engine Model ZT188F
Power 13.0HP
Engine Type Air-cooled; 4-stroke; OHV, Single Cylinder
Ignition System Transistor Magneto
Starting System Electric
Displacement  Max. Output 389cc
Max. Output 12kW
Fuel Tank Capacity 25L
Continuous Operating Time 8h
Min. Fuel Consumption 360g/kW.h
Noise Level 78dB
Lube. Oil Capacity 1.1L
8 Camera (photo taker) NIKON COOL PIX S2800DIGITAL CAMERA

Specifications:

Mega Pixel: 20.1 MP

Movie: VGA 30p

Optical Zoom: 5x NIKKOR glass lens

Storage: SD Card/SDHC Card/SDXC Card

AF System: 99 Points

LCD: 2.7 Inch

Battery: EN-EL19 ( 250 shots )

Or

Any equivalent Canon Model

Or

Sony DSC-W800:20.1 MP,5x optical zoom,up to 40 VGA, SO Auto: Approx. 1.3 to 11.5 ft (0.4 to 3.5 m)(W) / Approx. 1.96 to 5.77 ft (0.6 to 1.76 m) (T), ISO 3200: up to approx. 23 ft (7 m) (W) / Approx. 11.5 ft (3.5 m) (T), rechargeable battery pack NP-BN battery

 

 


 LOT2: Network Cabling Requirements

SID ITEM STANDARDS AND SPECIFICATIONS UNIT
9 RACK 9U pc
10 SWITCH 24 PORT DLINK pc
11 Patch Panel Cat 6 24 port pc
12 PDU   pc
13 SCREW M8 M8 pc
14 Network cable SFTP / UTP Cable Cat6 roll
15 PVC trucking PVC (100×50) LEGRAND pc
16 Patch cord (50cm) pc
17 Patch cord(2.5m) (2.5m) pc
18 Angle plat (100×50) LEGRAND pc
19 External Angle (100×50) LEGRAND pc
20 Internal Angle (100×50) LEGRAND pc
21 End Cap (100×50) LEGRAND pc
22 Tee (100×50) LEGRAND pc
23 Joint (100×50) LEGRAND pc
24 Mesh + SCREW 8mm Pc
25 connector RJ45 pc
26 Complete Data Socket Complete LEGRAND pc

 


Power Cabling Requirements

SID ITEM STANDARDS AND SPECIFICATIONS UNIT
27 socket (white) LEGRAND pc
28 socket (red) UPS LEGRAND pc
29 VOB cable OMAN 2.5mm m
30 ISOLET TAPE   pc
31 Change over Manual pc
32 Circuit breaker   pc
33 simple Fuse breaker   pc
34 Cable for Generator (4×2.5) m

N.B: Actual quantities might vary. Vendors must do a Site Survey and provide detailed quotation for equipment and wiring

  • TECHNICAL SPECIFICATIONS FOR UMURENGE SACCO LAN

1.1.2.      Technical Specifications

 

 

NETWORKING (CABLING), INSTALLATION AND CONFIGURATION AND SUPPLY OF IT EQUIPMENT IN UMURENGE SACCO

Scope of work for cabling, Installations and configurations

The bidder is expected to carry out activities related to networking (cabling) data and power, installation and configurations to all u-saccos:

Details on type of services, quantities, physical location, and places are provided below.

Sites visits

It is planned sites visits for the Networking (cabling), installation and configuration starting after the date of signing contract. Therefore, the selected companies will conduct prior sites visits.

Note: The Office should have grounding and Lighting protection where needed.

N.B: All expenses related to the sites visits should be entirely covered by the bidder who is conducting the visits.

Integrated Cabling Requirements

 Data /power system

All electrical sockets must be of ground E type or F-type. A data and electrical cable trucking system must be installed with power, data (RJ45). An estimate of the amount of electrical and data (STP/UTP cat6) cabling needed must be done after the bidders have visited and submitted in their site visit report.

Functional and description of components and Bidder should provide detailed pricing for each

  • RJ 45 terminal connector
  • Transition point for indirect cabling i.e. ceiling or floor.
  • Main distribution Rack/frame
  • STP Cable Schneidel
  • Underground PVC Trucking
  • complete Data Socket
  • Patch Cords
  • Circuit Breakers
  • Lightning Protection
  • Angel Plat Legrand

 

Data cabling convention

A. Terminal connectors/ information outlets (IO)

All station outlets shall be modular in design and contain one (1) wired 8 pin/8 conductor outlets (RJ-45)

To avoid installation errors, the wire organiser of the snap-in connector must be identified by the same standard colour coding as the wires. All Category 6 RJ45 connectors shall be fully compliant with the ISO/IEC 11801/8877:2002 standard.

 

The presentation of the outlet shall provide for labelling and identification. A transparent window shall protect the labelling tag.

  1. Horizontal Cabling/ Distribution Cable

 

The horizontal 4 pair cable shall be Category 6 UTP/STP cables to meet the quality and performance criteria necessary to ensure correct operation of the installation in future and compliance with the warranty.

 

The installation design and routing of all cables shall take account of the manufacturer limits for the continued performance of the cables and the compliance with the warranty.

 

All wiring is to be installed on the wall where practical. Where surface-mount is required, all wire must be in conduit or surface raceway. All surface mount products must be industrial grade and of a professional appearance.

  1. Cabinet

 

The metal cabinets can be mounted by means of the standard cage nuts. The front door consists of a metal framework with hinges and a central security glass.

 

The side panels and the panel in the back have to be equipped with a hinge on the left or the right in order to facilitate the access to the equipment.

 

 

D. A 24 Port modular patch panels (RJ45)

Patch panels must have 12″ equipment practice dimensions to permit mounting in standard cabinets, racks or bays. The vendor shall make their proposals for this tender using 24 ports Snap-in format (Modular) patch panels equipped with a cable management mechanism that provides strain relief, earthling and grounding features. The presentation of the Patch Panel shall provide for labelling using a printed numbering system.

 

  1. Patch-cords

To achieve a Class E Channel performance all Patch Cords will be Category 6 rated. The Category 6 cords must be fitted with Category 6 RJ45 plugs, booted at each connector. The characteristic impedance of the pairs must be identical to that of the horizontal cables. The Patch Cords shall have a guaranteed performance level of greater than 750 insertions without degradation to the performance level of the solution.

F. Acceptance of installation

The installation, configuration, and successful system operation will be validated on site before the client can accept the system.

Visual inspection will be performed to ensure that the installation done is in conformity with the specifications and professional standards.

 

  • LAN Cabling Requirements
S. No Title Specification Bidder’s Details

 

1 Scope of Work The bidder will deliver  the equipment and

Software (if applicable) and provide

Services to install and maintain LANs for a period of one year minimum warranty.

 
2 Functionality This network will connect the

Equipment to provide data connectivity for the users

 
3 Coordination The coordination will be provided by the SACCO Manager with support of U-SACCO computerization project  
4  

Site Visit

 The selected companies are advised to conduct site visits and provide a detailed diagrammatic representation of LAN cabling, UPS cabling and low Voltage Power Cabling to the computers and peripherals during bidding (will be after the selection of companies).  
5 Normal AC low Power and UPS power Supply

 

Only normal AC power should be supplied to the peripheral devices like printers etc with combined power socket and circuit breaker of 15A and 5A Power sockets and I/O outlets shall be properly nomenclature i.e. the socket should specify whether it bears UPS power or Normal AC power.  
6 Electric Power All active (powered) equipment must

Operate on 220v~, 50 Hz. All active equipment must include power plugs standard in Rwanda. All peripherals must be connected to raw power.

 

The Server Room will have dedicated power supply from the main with circuit breaker of 120 A.

 
7

 

 

UPS cabling

Installation

The Bidder will install UPS Cabling

terminating in UPS Power plug Surface

Mount box with fitting.

 
8 Environment Unless otherwise specified, all equipment must operate in environments of 10-40 degree centigrade or better, 20-90 percent

Relative humidity or better, and 0-40 grams per cubic meter of dust or better.

 
9 Noise Pollution Unless otherwise specified, all equipment must operate at noise levels no greater than 55 decibels.  
10

 

Environmental

Safety

 

All electronic equipment that emits

Electromagnetic energy must be certified as meeting US FCC class B or equivalent, emission standards.

 
11

 

Way of Quote

Submission

 

Bidders must quote the unit rate, where possible, of each component of LAN separately to accommodate the variations in the requirements.  
12 Cabling for LAN CAT 6 or substantially equivalent/better

UTP cable having support of high

Bandwidth with connectors.

Structured cabling (50×100) must be used

 
13

 

Mandatory Bidder must be able to do structured cabling as per industry standards / practices. All cabling work within LAN and UPS will be the responsibility of the bidder.  
Bidder shall repair all the damage that they may cause during the LANs installation (painting and remove all dust).
14

.

 

Networking and

Communications

Software.

Computers will use TCP/IP network

Protocol

 
15

 

Technical

management and

troubleshooting

 

Bidder must provide detailed plan for technical management and troubleshooting during life-cycle of the LANs.  
16

 

Facilities given

by the end user

 

Power usage during the LANs installation (for example drilling) shall be negotiated with the end user (SACCO).

All physical facilities required to support the establishment of LANs like civil works, cabling etc. shall be done by the bidder.

 
17 Warranty All the equipment and Software

will be covered by a

comprehensive warranty of at least

one (1) year. Please note that for the LAN the warranty period start after successful acceptance tests.

 
18

 

Technical

Documents

 

The bidder shall provide operational and maintenance manuals together with the drawings (details network design). The manuals and drawings for all supplied equipment shall be in English and in soft or hard copy and equal to the number of supplied equipment.  

 

19 Delivery Period Cabling should delivered in maximum of 3 days and IT equipment should be delivery in maximum of 30 days.  
20 Manufacturer All active LAN components such as switches, wireless equipment offered shall be of the same Make/manufacturer and shall be covered under same back-up guarantee, to ensure full compatibility, inter-working and inter-operability.

 

 
21 Documentation Network Documentation (on Paper and CD) that covers the installation, operation, care and maintenance of all system components including diagnostics; drawings indicating the cable routes, termination & termination details, actual configuration & parameters, etc.

 

 
30 Labelling Trucking’s should bear labels on data socket outlets which should have corresponding labels on the patch panels for easy management and troubleshoot and should also be in printed format.

 

 

 

Related posts

Uniform microfinance law crucial to increase financial inclusion in EAC, efficiency – AMIR

amir.rw

CEOs Round Table Meeting, November 2022

amir.rw

List of the Smart Assessors

amir.rw

1 comment

cosplay costumes November 30, 2019 at 11:48 am

Hi there to every one, the contents existing at this website are really amazing for
people experience, well, keep up the nice work fellows.

Reply

Leave a Comment